The unshielded installation cables for telephone and information processing systems should preferably be used as voice lines for telephone extensions and intercom units for fixed installation in dry and damp operating sites within buildings, on and under plastered surfaces, as well as for fixed laying on buildings’ external walls. These installation cables are not authorised for heavy current or underground installation. They are suitable for connecting office communication systems, telephone, fax and burglar alarm systems, operating data recording devices, door intercoms and two-way intercom systems. Installation advice: when laid, these cables must be unwound from the coil or ring without any twists or kinks.


Telephone Cables
When installing in buildings or connecting cities or larger distances, certain cables and wires quickly come into play: telephone lines. When choosing them, you should pay attention to factors such as attenuation losses, data transmission speeds, fire protection, water protection, and weight. This is because each telephone line offers certain advantages and properties, and each model has its own specific areas of use.
At elmat, you can choose from a wide range of different cables and wires. Surely, there is something suitable for you among them!
Our models at a glance:
J-YY Telecommunication cable

J-Y(St)Y Telecommunication cable

This cable is used as a voice line in intercom units and telephone extensions for fixed installation in dry and damp rooms, as well as on external walls, protected against direct sunlight. Also for outdoor use. Not suitable for burying underground. The static shield made from plastic-laminated metal foil protects the cable circuits against external electrical interferences to maintain the necessary capacitive coupling values and ensure accurate pulse transmission. Installation advice: when laid, these cables must be unwound from the coil or ring without any twists or kinks.
J-Y(St)Y Fire signalisation cable

This cable is used as a voice line in intercom units and telephone extensions for fixed installation in dry and damp rooms, as well as on external walls, protected against direct sunlight. Not suitable for burying underground. The static shield (St) made from plastic-laminated metal foil protects the cable circuits against external electrical interferences to maintain the necessary capacitive coupling values and ensure accurate pulse transmission. The cable sheaths are labelled at regular intervals with the text ‘fire alarm cable’. Installation advice: when laid, these cables must be unwound from the coil or ring without any twists or kinks.
J-2Y(St)Y ST III Bd ISDN - cable

ISDN-compatible data cable for the transmission of analogue and digital signals at up to 16 Mbits/sec. It is used, for example, to connect EDP system units or within circuits designed with the highest safety and speed requirements for airfield lighting, ISDN intercommunication systems, systems for recording operating data, access control and time recording systems, industry electronics and alarm systems. Use in dry and damp rooms for fixed installation on and under plastered surfaces.
J-2Y(St)H ST III Bd LSOH ISDN cable

ISDN-compatible data cable with halogen-free outer sheath for the transmission of analogue and digital signals at up to 16 Mbits/sec. It is used, for example, to connect EDP system units or within circuits designed with the highest safety and speed requirements for airfield lighting, ISDN intercommunication systems, systems for recording operating data, access control and time recording systems, industry electronics and alarm systems. Use in dry and damp rooms for fixed installation on and under plastered surfaces.
J-H(St)H LSOH telecommunication cable

This cable is used as a voice line in intercom units and telephone extensions for fixed installation in dry and damp rooms as well as on external walls, protected against direct sunlight. Also for outdoor use. Not suitable for burying underground. It is halogen free and highly flame retardant. The static shield made from plastic-laminated metal foil protects the cable circuits against external electrical interferences to maintain the necessary capacitive coupling values and ensure accurate pulse transmission. Installation advice: when laid, these cables must be unwound from the coil or ring without any twists or kinks.
J-H(St)H BMK LSOH fire signalisation cable

This cable is used as a voice line in intercom units and telephone extensions for fixed installation in dry and damp rooms, as well as on external walls, protected against direct sunlight. Also for outdoor use. Not suitable for burying underground. It is halogen free and highly flame retardant. The static shield made from plastic-laminated metal foil protects the cable circuits against external electrical interferences to maintain the necessary capacitive coupling values and ensure accurate pulse transmission. Installation advice: when laid, these cables must be unwound from the coil or ring without any twists or kinks.
JE-H(St)H Bd FE180 E30/E90 Fire resistant cable

As an installation cable for telecommunication purposes for fixed laying in fire risk areas where particular protection against fire and fire damage is required for people and property and a system’s functional integrity must be maintained for 30 or 90 minutes. The cable has an insulation integrity of at least 180 minutes. The functional integrity is guaranteed under a test voltage of 110 V. The cable should be laid within buildings. When using a tube, the cables can also be laid outdoors or underground. During installation, the general test certificates issued by the cable and carrier system manufacturer must be observed. Also suitable for use as a fire alarm cable with a red outer sheath.
JE-H(St)H Bd FE180/E30 Fire resistant cable

As an installation cable for telecommunication purposes for fixed laying in fire risk areas where particular protection against fire and fire damage is required for people and property and a system’s functional integrity must be maintained for 30 minutes. The cable has an insulation integrity of at least 180 minutes. The functional integrity is guaranteed under a test voltage of 110 V. The cable should be laid within buildings. When using a tube, the cables can also be laid outdoors or underground. During installation, the general test certificates issued by the cable and carrier system manufacturer must be observed. Also suitable for use as a fire alarm cable with a red outer sheath.
JE-H(St)H Bd FE 180/E90 Fire resistant cable

As an installation cable for telecommunication purposes for fixed laying in fire risk areas where particular protection against fire and fire damage is required for people and property and a system’s functional integrity must be maintained for 90 minutes. The cable has an insulation integrity of at least 180 minutes. The functional integrity is guaranteed under a test voltage of 110 V. The cable should be laid within buildings. When using a tube, the cables can also be laid outdoors or underground. During installation, the general test certificates issued by the cable and carrier system manufacturer must be observed. Also suitable for use as a fire alarm cable with a red outer sheath.
JE-H(St)HRH Bd FE180/E90 Fire resistant cable

For signal transmission in measuring, data and control technology systems and as an installation cable in fire risk areas with a high concentration of people or material assets. For setting up cable systems with an integrated functional integrity according to DIN 4102 T.12. For fixed installation in dry and damp rooms.
A2Y(L)2Y…ST III Bd Telephone subscriber line cable

Local connection cables for telecommunication systems in operating and industrial facilities for direct installation underground, in cable ducts and tubes. They are not authorised for heavy current installation purposes. The PE material is halogen free but not flame retardant. The black PE sheath is resistant to UV rays. The cable is transversely waterproof.
A2Y F (L)2Y…ST III Bd Telephone subscriber line cable

Local connection cables for telecommunication systems in operating and industrial facilities for direct installation underground, in cable ducts and tubes. They are not authorised for heavy current installation purposes. The PE material is halogen free but not flame retardant. The black PE sheath is resistant to UV rays. The cable is transversally and longitudinally waterproof.
A02YS F (L)2Y…ST III Bd Telephone subscriber line cable

Local connection cables for telecommunication systems in operating and industrial facilities for direct installation underground, in cable ducts and tubes. They are not authorised for heavy current installation purposes. The PE material is halogen free but not flame retardant. The black PE sheath is resistant to UV rays and weather conditions. This cable offers a particularly notable weight advantage in the case of high numbers of pairs.
EIB-BUSLEITUNG Y(St)Y With static shield

The higher test voltage and labelling make this cable ideal for the transmission of BUS signals in the field of buildings system technology. This particularly applies for the European installation bus (EIB). The EIB BUS cable has been EIBA-certified to no. 1/39/92 and fulfils the requirements for bus cables established in DIN VDE 0829 and pr EN 5009-2. EIB BUS cables YCYM can be laid on, within and under plastered surfaces, in tubes and installation ducts, in dry, damp and wet rooms and outdoors – providing they are protected against direct sunlight. They can be laid alongside and touch heavy current cables. Only one core pair (red/white) is needed for the installation bus EIB, via which both the 24 V bus current and data telegrams can be transmitted. The second core pair is used as a reserve or for special purposes.
EIB-BUS cable J-H(St)H FRNC With static shield

The higher test voltage and labelling make this cable ideal for the transmission of BUS signals in the field of buildings system technology. This particularly applies for the European installation bus (EIB). The EIB BUS cable has been EIBA-certified to no. 1/39/92 and fulfils the requirements for bus cables established in DIN VDE 0829 and pr EN 5009-2. EIB BUS cables YCYM can be laid on, within and under plastered surfaces, in tubes and installation ducts, in dry, damp and wet rooms and outdoors – providing they are protected against direct sunlight. They can be laid alongside and touch heavy current cables. Only one core pair (red/ white) is needed for the installation bus EIB, via which both the 24 V bus current and data telegrams can be transmitted. The second core pair is used as a reserve or for special purposes.
What exactly are telephone lines?
Telephone lines are used for installation in buildings and for connecting cities or larger distances. They are characterized by low attenuation losses and high data transmission speeds. They are used as an interface to the consumer to transmit analog and digital telecommunications signals over short distances from the building handover point to the respective end devices.
Which telephone lines are available?
Here you can get an overview of the different lines and cables.
Telecommunication Cables
Telecommunication cables consist of individual wire pairs or quads inside. These are enclosed with a more or less complex protection and identification system made of papers, foils, threads, and sheaths.
Different numbers of wire pairs, different areas of application: The smallest cable contains six wire pairs and is mostly used as a house connection cable for houses with a maximum of two residential units. The largest cables, with 2,000 wire pairs, are used as feeder cables, known as local connection cables, for districts or streets and end in cable distributors, or they connect local exchange offices. Nowadays, cost-effective fiber optic cables are often installed, which, despite their significantly smaller cross-section, can transmit a much larger amount of data.
Subscriber Cables
Subscriber cables are suitable for shorter distances, such as telephone connection cables for connecting telephone stations with exchanges or linking exchanges with each other, as well as connection cables in industrial and commercial facilities.
They are also considered local connection cables and can be used for telecommunications systems in industrial and commercial facilities and for direct installation in the ground, cable ducts, and pipes.
Bus Cables
Bus cables are used in industrial communication for digital signal transmission, e.g., between sensors and their corresponding evaluation units.
Bus cables surpass standard data cables due to their high transmission speeds and data transfer rates of up to 10 Gbit. These properties are needed, for example, in parcel conveyor systems, sorting units in recycling plants, and waste glass sorting units, as they require lightning-fast transmissions, evaluations, and reactions.
Why buy telephone cables from elmat?
Whether telephone cables, telecommunication cables, or bus cables: Our products deliver what they promise. You can rely on our online shop to offer only cables and wires that we fully stand behind.
Do you have any questions about our cables or other products? Then don’t hesitate to contact us! Our trained team will be happy to assist you. We look forward to hearing from you!