Halogen-free cables

Halogen-free cables and wires from elmat do not contain halogens such as chlorine, fluorine, or bromine in the insulation and sheath material of the cable or wire. They not only provide protection against fire and fire damage but also prevent the spread of a fire when exposed to flames.

Our models at a glance:

all open
close all

NHXMH LSOH building wire

elmat_nhxmh.jpg

For laying over, on, in and under plastered surfaces, in dry, damp and wet rooms, as well as in brickwork and concrete. Not suitable for direct embedding in shake, vibrated or tamped concrete. For installation in buildings with high concentrations of people and/or material assets. These cables have also been approved for outdoor use providing they are protected against direct sunlight. Special features: these Halogen free cables have minimum smoke emissions. No corrosive and toxic gases are discharged. If exposed to fire, they prevent this from spreading.

N2XH FRNC power cable 0.6/1kV

elmat_n2xh.jpg

For wherever particular protection against fire and fire damage is required for people and property and high safety requirements have to be fulfilled. Suitable for both indoor and outdoor use. For laying over, on, within and under plastered surfaces but not directly in soil or water. If exposed to fire, they prevent this from spreading and generate extremely little smoke. No corrosive and toxic gases are discharged. The cables are classed as having protective insulation.

N2XCH FRNC power cable 0.6/1kV

elmat_n2xch.jpg

For wherever particular protection against fire and fire damage is required for people and property and high safety requirements have to be fulfilled. For indoor installation over, on, in and under plastered surfaces, in dry, damp and wet rooms, as well as in brickwork and concrete. Also suitable for outdoor use. Do not bury directly in soil or lay in water. If exposed to fire, they prevent this from spreading and generate extremely little smoke. No corrosive and toxic gases are discharged. The cables are classed as having protective insulation.

(N)HXH FE180/E30 Fire resistant cable

elmat_n-hxh_fe180-e30.jpg

For wherever particular protection against fire and fire damage is required for people and property and high fail-safe periods have to be complied with, for example at airports, in hospitals and in schools. Suitable for both indoor and outdoor use but not for direct burying in soil or laying in water. The fire-induced smoke formation that makes it impossible to find emergency exits and the emission of toxic gases are prevented. The insulation integrity of at least 180 minutes and functional integrity of at least 30 minutes ensure that fire detection and alarm systems, safety lighting and other backup lighting remain functional.

(N)HXH FE180/E90 Fire resistant cable

elmat_n-hxh_fe180-e90.jpg

Safety cables are used wherever particular protection against fire and fire damage is required for people and property and high fail-safe periods have to be complied with, e.g. at airports, in hospitals and in schools. Suitable for both indoor and outdoor use but not for direct burying in soil or laying in water. The fire-induced smoke formation that makes it impossible to find emergency exits and the emission of toxic gases are prevented. The insulation integrity of at least 180 minutes, functional integrity of at least 90 minutes and reliability of over 90 minutes ensure the continued functional capability of water-pressure boosting equipment for supplying fire extinguishing water, ventilation systems, smoke and heat extraction systems, fire brigade lifts etc.

(N)HXCH FE180/E30 Fire resistant cable

elmat_n-hxch_fe180-e30.jpg

For wherever particular protection against fire and fire damage is required for people and property and high fail-safe periods have to be complied with, for example at airports, in hospitals and in schools. Suitable for both indoor and outdoor use but not for direct burying in soil or laying in water. No toxic gas emissions in the event of fire. Insulation integrity of at least 180 minutes and functional integrity of at least 30 minutes. Reliability of over 30 minutes ensures that fire detection and alarm systems, safety lighting and other backup lighting remain functional.

(N)HXCH FE180/E90 Fire resistant cable

elmat_n-hxch_fe180-e90.jpg

Safety cables are used wherever particular protection against fire and fire damage is required for people and property and high fail-safe periods have to be complied with, e.g. at airports, in hospitals and in schools. Suitable for both indoor and outdoor use but not for direct burying in soil or laying in water. The fire-induced smoke formation that makes it impossible to find emergency exits and the emission of toxic gases are prevented. The insulation integrity of at least 180 minutes, functional integrity of at least 90 minutes and reliability of over 90 minutes ensure the continued functional capability of water-pressure boosting equipment for supplying fire extinguishing water, ventilation systems, smoke and heat extraction systems, fire brigade lifts etc.